| Name | Ductless Fume Hood |
| Code | scitek-0095 |
| Type | Standard |
| Brand | Scitek |
| Category | Laboratory Ventilation |
| subcategory | Ductless Fume Hood |
| Unit | pcs (pcs) |
| In Stock | Yes |
| Berminat hub kami: | |
Filter : Active Carbon filter (1pcs), Pre-filter(1pcs)
Max. Opening : 650mm
Air-velocity Range : 0.4-0.6m/s
Optional Accessory : Base stand, HEPA filter, Base Cabinet, Optional upgrade LED lamp
Ductless fume hood series with 7" colour screen showing all operational status of each function. Now the best budget ductless chemical fume hood for sale at cost price.
Ductless fume hood (also known as a ductless fume hood, portable chemical hood), which uses carbon or HEPA filtration to protect laboratory personnel from toxic chemical fumes, odours and particles. Real-time adsorption and treatment of airborne solvents, acid gases, formaldehyde and other hazardous substances. The air in the lab is then circulated and cleaned.
Ductless Fume Hood Specifications:
| Model | FMH-800DL |
|---|---|
| External Size (WxDxH)(mm) | 800x620x1130 (Without Base Stand) 800x620x1800 (With Base Stand) |
| Operation Area Size (WxDxH)(mm) | 780x540x775 |
| Operation Surface Height | 690mm |
| Max. Opening | 650mm |
| Air Velocity | Adjustable, 0.4-0.6m/s |
| Audio and Visual Alarm | Filter life; VOC contentration; Abnormal air speed |
| Touch Screen | 7-inch color screen with graphical and digital display of all the operating status of each function, such as filter life, voc, temperature and humidity etc |
| Blower | DC centrifugal blower, adjustable speed |
| Front Window | Manual acrylic window |
| Filter | Active Carbon filter (1pcs), Pre-filter(1pcs) |
| LED lamp | Standard general LED lamp (Color Rendering Index: Ra70~85) Optional upgrade LED lamp (Color Rendering Index: Ra98; RG0 without blue light) |
| Power Consmption | 60W |
| Sound Emission | <50dB(A) |
| Power Supply | AC110V-230V, 50/60Hz |
| Shipping Size (W×D×H) | 950x830x1300mm |
| Gross Weight | 120KG |
| N.W/G.W | 65kg/99kg |
| Shipping Volume | 1.03m3 |
| Standard Accessory | Active Carbon Filter, Pre-filter, LED lamp |
| Optional Accessory | Base stand, Base Cabinet, HEPA filter, Optional upgrade LED lamp |
This type of fume hood utilizes optional HEPA filtration to protect laboratory personnel from particles, if add optional carbon or chemical filters could also protect laboratory personnel from toxic chemical fumes, odors. Known for its plug-and-play feature and mobility, ductless fume hood guarantees a hassle-free installation and no lab work interruption.
Ductless Fume Hood Feature:
Powerful filtration system can be configured with HEPA filters and chemical filters according to customer requirements, effectively filtering and removing harmful substances to ensure a safe operating environment and protect personnel from harm.
Easy to operate, and fume hood equipped with a 7-inch LCD color touchscreen, it displays real-time parameters such as air velocity, VOC concentration, temperature and humidity, and filter lifetime. This achieves excellent human-machine interaction.
Humanized design, three-sided acrylic transparent material observation window, convenient for multi-angle observation.
Low noise design, using high-quality DC centrifugal blower to ensure performance while providing users with a quiet working environment.
Memory function in case of power-failure.
Audio and Visual alarm on filter life,VOC concentration
Brushed stainless steel work surface is for easy cleaning.
Different sizes available from 2 feet to 6 feet, benchtop use or mounted on a mobile base.
Optional upgrade LED lamp can be choosed.
Color Rendering Index up to Ra98, Truly restore the true color of the experimental object, the experimental results are more accurate.
RG0 without blue light, protects the operator from blue light.
Details of Ductless Fume Hood:


The fronts of the ductless fume hood is equipped with advanced control panels and high-definition shields to ensure a clear view of the operations inside the cabinets.

The streamlined sides of this ductless fume hood make it a focal point in the laboratory environment and provide excellent ventilation.


The top suction opening and ductwork are the core components of the ductless fume hood, ensuring efficient airflow circulation and the discharge of harmful gases.


We use sturdy packing materials and foam padding to protect the equipment from damage during transport. Each unit is carefully packed to ensure that it will not be affected by impact or vibration during transport.
Difference between ductless and ducted fume hoods?
Ducted fume hoods can be filtered or unfiltered depending on the design and application. Ductless fume hoods contain filters which clean contaminated air and recirculate it directly back into the laboratory. No additional ductwork is required to exhaust air to the outside.
Which is better ducted or ductless?
Ducted air conditioners are ideal for big, centralized systems throughout the building. Air is collected from the space and cooled. After that, it is moved to your indoor rooms through ducts. Ductless systems are suitable for smaller areas such as single rooms or apartments.
Are ductless fume hoods safe?
Yes, ductless fume hoods are safe when used correctly. They use filtration systems to remove hazardous fumes and particulates from the air, protecting users and the environment. However, proper maintenance and adherence to safety protocols are essential for ensuring their effectiveness.
Why Scitek
18 Months Limited Warranty
CE and FDA Standards
1-2 Days Handling and 7-30 Days Shipping
Arabic
French
German
Indonesian
Italian
Portuguese-brazilian
Simplified-chinese
Spanish
Thai
Traditional-chinese
Turkish
Vietnamese


