Bante900 Benchtop pH/Ion/Conductivity/DO Meter (bante-0023) Products
Name Bante900 Benchtop pH/Ion/Conductivity/DO Meter
Code bante-0023
Type Standard
Brand Bante
Category pH Meters
subcategory Benchtop Meters
Unit pcs (pcs)
In Stock Yes
Berminat hub kami: wa chat
Product details for Invoice
Professional benchtop pH meter, containing 17 setting options, suitable for measuring pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and DO.
Product Details

Bante900 Benchtop pH/Ion/Conductivity/DO Meter

Professional benchtop pH meter, containing 17 setting options, suitable for measuring pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and DO.

pH Mode:
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
• Automatic electrode diagnosis shows the pH slope and zero offset.

ORP Mode:
• 1 point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt modes ensure the reliable ORP measurements.

pH Ion Conductivity DO Meter

Ion Concentration Mode:
• 2 to 5 points calibration, including the selection of 8 concentration points.
• Automatic electrode diagnosis shows the calibration points and slopes.
• Direct ion concentration readout simplifies the measurement process.
• Selectable concentration units (ppm, mg/L, mol/L) and ionic valency.

Conductivity/TDS/Salinity/Resistivity Modes:
• 1 to 5 points calibration with automatic recognition for conductivity standards.
• Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear and
  pure water compensations, seawater and practical salinity measurement modes.

Dissolved Oxygen Mode:
• 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
• Salinity and barometric pressure compensations eliminate the measurement errors.

pH Ion Conductivity DO Meter

Other Features:
• Automatic temperature compensation ensures accurate readings over the entire range.
• Auto-read function senses and locks the measurement endpoint.
• Calibration due alarm reminds the user to calibrate the meter regularly.
• Setup menu allows setting the number of calibration points, stability criteria, temperature unit,
  date and time, auto-power off, etc.
• Reset function automatically resumes all settings back to the factory defaults.
• Expanded memory stores or recalls up to 500 data sets.
• USB communication interface for data transfer and timed interval readings.

Specification

   Model


Bante900

   pH



   Range


-2.000 to 20.000 pH

   Resolution


0.001 / 0.01 / 0.1 pH, selectable

   Accuracy


±0.002 pH

   Calibration


1 to 5 points

   pH Buffer Options


USA / NIST / DIN / 2 custom buffers

   ORP



   Range


-1999.9 to 1999.9 mV

   Resolution


0.1 / 1 mV, selectable

   Accuracy


±0.2 mV

   Calibration


1 point

   Measurement Modes


Relative / Absolute mV

   Ion Concentration



   Range


0.00 to 19999 (depending on the range of ISE)

   Resolution


0.001, 0.01, 0.1, 1, automatic

   Accuracy


±0.5% F.S. (monovalent), ±1% F.S. (divalent)

   Calibration


2 to 5 points

   Calibration Solutions


0.001 / 0.01 / 0.1 / 1 / 10 / 100 / 1000 / 10000

   Measurement Units


ppm, mg/L, mol/L, mmol/L

   Conductivity



   Range


0 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm

   Resolution


0.001, 0.01, 0.1, 1, automatic

   Accuracy


±0.5% F.S.

   Calibration


1 to 5 points

   Calibration Solutions


10 µS / 84 µS / 1413 µS / 12.88 mS / 111.8 mS

   Temperature Coefficient


0.0 to 10.0%/°C

   Pure Water Compensation


Yes

   Reference Temperature


20 / 25°C

   Cell Constant  


K=0.1 / 1 / 10 / Custom

   TDS



   Range


0 to 10.00, 100.0, 1000 ppm, 10.00, 200.0 ppt

   Resolution


0.01, 0.1, 1, automatic

   Accuracy


±1% F.S.

   TDS Conversion Factor


0.1 to 1.0 (default 0.5)

   Salinity



   Range


0.00 to 80.00 ppt / 0.00 to 42.00 psu

   Resolution


0.01

   Accuracy


±1% F.S.

   Resistivity



   Range


0.00 to 20.00 MΩ

   Resolution


0.01

   Accuracy


±1% F.S.

   Dissolved Oxygen



   Range


0.00 to 20.00 mg/L / 0.0 to 200.0 % saturation

   Resolution


0.01 / 0.1, selectable

   Accuracy


±0.2 mg/L / ±2.0 %

   Calibration


1 or 2 points

   Pressure Correction


60.0 to 112.5 kPa / 450 to 850 mmHg, manual

   Salinity Correction


0.0 to 50.0 g/L, manual

   Temperature



   Range


0 to 105°C / 32 to 221°F

   Resolution


0.1°C/°F

   Accuracy


±0.5°C / ±0.9°F

   Calibration


1 point

   Calibration Range


Reading ±10°C/°F

   Other Specifications



   Temperature Compensation

0 to 100°C / 32 to 212°F, manual or automatic

   Hold Function

Manual / Auto-read measurement endpoint

   Stability Criteria

Low / High

   Calibration Due Alarm

1 to 31 days or off

   Memory

Stores up to 500 data sets

   Output

USB communication interface

   Connector

BNC, 6-pin mini-DIN, 3.5 mm jack socket

   Display

Custom LCD (125 × 100 mm)

   Power Supply

5V DC power adapter

   Environmental Conditions

0 to 50°C / 32 to 122°F, relative humidity < 80%

   Dimensions

210 × 188 × 60 mm

   Weight

1.5 kg

Ordering Info

   Ordering Code

Meter Includes

   Bante900-CN

E201-BNC pH electrode

CON-1 conductivity electrode

DO100 dissolved oxygen electrode

TP-10K temperature probe

pH 4.01, 7.00, 10.01 buffer reagents

Conductivity standard solutions 84 µS/cm, 1413 µS/cm, 12.88 mS/cm

DO electrolyte solution

DO membrane cap

USB cable

5V DC power adapter

   Bante900-UK

   

P11 glass pH electrode

K10 conductivity electrode

DO100 dissolved oxygen electrode

TP-10K temperature probe

pH 4.01, 7.00, 10.01 buffer reagents

Conductivity standard solutions 84 µS/cm, 1413 µS/cm, 12.88 mS/cm

DO electrolyte solution

DO membrane cap

USB cable

5V DC power adapter

Optional Accessories

ItemsDescription
E201-BNC pH ElectrodeFor measuring the liquids
E202-BNC pH ElectrodeFor measuring the semisolid and gel samples
P11 pH ElectrodeFor measuring the weak corrosive samples
P11-LiCl pH ElectrodeFor measuring the non-aqueous samples
P11-HA pH ElectrodeFor measuring the high alkalinity samples
P11-NA pH ElectrodeFor measuring the biofuels
P13 pH ElectrodeFor measuring the micro-volume samples
P15 pH ElectrodeFor measuring the low conductivity samples
P16 pH ElectrodeFor measuring the Tris buffers
P19 pH ElectrodeFor measuring the semisolid samples
P22 pH ElectrodeFor measuring the high temperature samples
501 ORP ElectrodeFor measuring samples with weak redox potential
502 ORP ElectrodeFor measuring samples with strong redox potential
ISE-NH3 Ammonia ElectrodeRange: 0.01 to 17000 ppm
ISE-NH4 Ammonium ElectrodeRange: 0.1​ to 18000 ppm
ISE-Br Bromide ElectrodeRange: 0.4 to 81000 ppm
ISE-Cd Cadmium ElectrodeRange: 0.1 to 11200 ppm
ISE-Ca Calcium ElectrodeRange: 0.02 to 40100 ppm
ISE-Cl Chloride ElectrodeRange: 1 to 35000 ppm
ISE-Cu Copper ElectrodeRange: 0.06 to 6400 ppm
ISE-CN Cyanide ElectrodeRange: 0.03 to 260 ppm
ISE-F Fluoride ElectrodeRange: 0.02 to 1900 ppm
ISE-I Iodide ElectrodeRange: 0.06 to 127000 ppm
ISE-Pb Lead ElectrodeRange: 0.2 to 20800 ppm
ISE-NO3 Nitrate ElectrodeRange: 0.4 to 62000 ppm
ISE-K Potassium ElectrodeRange: 0.04 to 39000 ppm
ISE-Ag Silver ElectrodeRange: 0.01 to 107900 ppm
ISE-Na Sodium ElectrodeRange: 0.002 to 69000 ppm
ISE-S Sulfide ElectrodeRange: 0.003 to 32000 ppm
CON-0.1 Conductivity ElectrodeFor measuring the pure water
CON-1 Conductivity ElectrodeFor measuring the general water samples
CON-10 Conductivity ElectrodeFor measuring the high conductivity samples
DO100 Dissolved Oxygen ElectrodeFor measuring the DO and % saturation of oxygen
TP-10K Temperature ProbeFor temperature compensation and measurement
pH Buffer SolutionsFor pH calibration
pH Electrode Storage SolutionFor electrode maintenance and storage
pH Electrode Cleaning SolutionFor general cleaning
pH Electrode Cleaning SolutionFor removing the protein contamination
Ion Standard SolutionsFor ion concentration calibration
Ionic Strength AdjustersFor adjusting the pH and background ionic strength
Conductivity Standard SolutionsFor conductivity calibration
DO Electrolyte SolutionFor filling the dissolved oxygen electrode
DO Membrane CapFor polarographic dissolved oxygen electrode

Packaging

   Ordering Code

Dimensions and Weights

   Bante900-CN

30 × 25 × 20 cm, 1.7 kg

   Bante900-UK

30 × 25 × 20 cm, 1.7 kg