| Name | Mini Dry Bath |
| Code | scitek-0932 |
| Type | Standard |
| Brand | Scitek |
| Category | PCR Analyzer and Pretreatment |
| subcategory | Dry Block Incubators |
| Unit | pcs (pcs) |
| In Stock | Yes |
| Berminat hub kami: | |
Display : LCD
Temperature Control Accuracy (℃) : ±0.5
Temperature Display Accuracy (℃) : 0.1
Max. Heating Rate : 8℃/min; 6.5℃/min
Size(W×D×H)(mm) : 145×113×110; 145×113×140
Available in personal sized with precision temperature control
Mini Dry Bath Specifications:
| Model | DB-MiniC100 | DB-Mini100 |
|---|---|---|
| Display | LCD | LCD |
| Temperature Setting Range (℃) | 0-100 | 25-100 |
| Temperature Range (℃) | RT.-23~100℃ | RT.+5~100℃ |
| Temperature Control Accuracy (℃) | ±0.5 | |
| Temperature Display Accuracy (℃) | 0.1 | |
| Minimum Time Taken for Heating (25℃-100℃) | ≤20min | |
| Minimum Time for Cooling (20℃-10℃) | ≤25min | / |
| Max. Heating Rate | 8℃/min | 6.5℃/min |
| Max. Cooling Rate | 3℃/min | / |
| Time Setting Range | 0-999min/0-999sec | 0-999min/0-999sec |
| No. of Programs in Memory | 9 (2 steps for each) | |
| Rapid Calibration | Support | |
| USB Interface | Support | |
| Error Code Reminder | Support | |
| Power Supply | AC100V-240V, 50Hz/60Hz | |
| Consumption | 60W | |
| Operation Temperature (℃) | -30 | |
| Operation Humidity (%RH) | ≤80 | |
| Size (W×D×H)(mm)(Without the Heating Block) | 250x240x200 | |
| Shipping Size (W×D×H)(mm) | 320x260x240 | |
| N.W./G.W. (kg) | 1.8/3 | |
| Optional Blocks | ||
| Cat. No. | Capacity | Diameter×depth |
| 18900414 | 40×0.2 mL | 6.4mm×20mm |
| 18900415 | 24×0.5 mL | 8.2mm×28.4mm |
| 18900416 | 15×1.5 mL | 11.2mm×31mm |
| 18900428 | 15×2 mL | 11mm×31mm |
| 18900417 | 6×5 mL | 17mm×31mm |
| 18900426 | 4×15 mL | 16.4mm×45mm |
| 18900427 | 2×50 mL | 29mm×45mm |
Mini Dry Bath Feature:
Compact design, small size, easy to carry, it is the ideal mobile heating equipment in the laboratory.
The dry bath is equipped with LCD, it can intuitively display the current temperature and operation time, allowing users to monitor the experimental conditions in real-time.
Temperature control accuracy of ± 0.5 ℃ to ensure the accuracy and repeatability of the experimental results.
Provide a variety of heating modules to choose from to meet the needs of different experimental operations.
Supports quick calibration mode, simplifying the operation process and improving the convenience of use.
Built-in over-temperature protection, effectively preventing the temperature from exceeding the set range.
Rapid warming and cooling capabilities will improve the efficiency of the experiment.
Arabic
French
German
Indonesian
Italian
Portuguese-brazilian
Simplified-chinese
Spanish
Thai
Traditional-chinese
Turkish