Multi-Parameter Patient Monitor (scitek-0630) Products
Name Multi-Parameter Patient Monitor
Code scitek-0630
Type Standard
Brand Scitek
Category Medical Device
subcategory Patient Monitor
Unit pcs (pcs)
In Stock Yes
Berminat hub kami: wa chat
Product details for Invoice
Model : MPM-IT

Heart Rate : 15-300 BPM (Adult);15-350 BPM (Neonatal)
Resolution : 1 BPM
Accuracy : ±1%
Sensitivity : >200 uV(Peak to peak)
Multi-parameter patient monitors are easy to use and can be easily updated and reconfigured.
Product Details

Multi-Parameter Patient Monitor Features:

  1. 12.1-inch touch screen display

  2. USB interfaces support easy software upgrade and data transfer

  3. Compatible with Central Monitoring System (CMS)

  4. Three Working Modes: Monitoring, Surgery and Diagnosis

  5. Simple and friendly operating display interface.

  6. Multi-display modes suitable for different applications: Standard Interface, Large font, ECG Standard Full Display, OXY, Trend Table, BP Trend

  7. Built-in high capacity battery up to 3 hours of continuous work

  8. VGA output for external display

Multi-Parameter Patient Monitor Specifications:

ModelMPM-IT
ECGLead Mode5 Leads (I, II, III, AVR, AVL, AVF, V)
Gain2.5mm/mV; 5.0mm/mV; 10mm/mV; 20mm/mV
Heart RateHeart Rate15-300 BPM (Adult); 15-350 BPM (Neonatal)
Resolution1 BPM
Accuracy±1%
Sensitivity>200 uV(Peak to peak)
ST Measurement RangeMeasurement Range-2.0 ~ +2.0 mV
Accuracy-0.8mV~+0.8mV: +0.02mV or ±10%, which is greater
Other Rangeunspecified
Sweep Speed12.5 mm/s, 25mm/s, 50mm/s
BandwidthDiagnostic0.05~130 Hz
Monitor0.5~40 Hz
Surgery1~20 Hz
SpO2Measuring Range0~100 %
Resolution1%
Accuracy70%~100% (±2 %)
Pulse RateRange20-250 BPM
Resolution1 BPM
Accuracy±3 BPM
Optional ParametersRecorder (Printer)
Central monitoring system
Dual IBP
Etco2
12-lead ECG
Nellcor SpO2
Sun Tech NIBP
NIBPMethodOscillometry
Measure modeManual, Auto, STAT
UnitmmHg, kPa
Measure and alarm range:
Adult ModeSYS40~280mmHg
DIA10~225 mmHg
MEAN20~240 mmHg
Pediatric ModeSYS40~220 mmHg
DIA10~160 mmHg
MEAN20~170 mmHg
Neonatal ModeSYS40~135 mmHg
DIA10~100 mmHg
MEAN20 ~110 mmHg
Resolution1 mmHg
Accuracy±5 mmHg
TEMPMeasure and Alarm Range0~50℃
Resolution0.1℃
Accuracy±0.1℃
RESPMethodlmpedance between RA-LI or RALA
Measurement RangeAdult10~120 BrPM
Neonatal/Pediatric7~150 BrPM
Resolution1 BrPM
Accuracy±2 BrPM
Power SupplyAC100-240V,50/60Hz
Shipping Size(W×D×H)(mm)370x280x360
G.W. (kg)5
Standard Configuration
No.ltemQty
1Main Unit1
25-lead ECG cable1
3Disposable ECG Electrode6
4Adult SpO2 probe1
5Adult NIBP Cuff1
6Temperature Probe1
7NlBP Extension Tube1
8Power Cable1
9User Manual1
10Fuse3