Atomic Absorption Spectrophotometer (scitek-0706) Products
Name Atomic Absorption Spectrophotometer
Code scitek-0706
Type Standard
Brand Scitek
Category Spectrophotometer and Colorimeter
subcategory Atomic Absorption Spectrophotometer
Unit pcs (pcs)
In Stock Yes
Berminat hub kami: wa chat
Product details for Invoice
Model : SP-AA4530

Wavelength Range : 190-900nm
Accuracy of the Wavelength : ±0.15nm
Receptivity of the Wavelength : ≤0.04nm
Size(W×D×H)(mm) : 730×625×700
Product Details

Atomic Absorption Spectrophotometer Specifications:

ModelSP-AA4530
Wavelength Range190-900nm
Spectral Bandwidth0.1/0.2/0.4/1.0/2.0 nm
Accuracy of the Wavelength±0.15nm
Receptivity of the Wavelength≤0.04nm
Base Line Stability≤0.002A/30min (Cu)
Characteristic Viscosity0.02μg/ml/1% (Cu)
Checking Limit0.004μg/ml (Cu)
Preciseness0.005
Grating1800 lines/mm
InflamerAll-metal titanium burner
AtomizerEffective glass atomizer
Lamp Stand8
D2 Background Correction Ability

When the background is 1A, the background ability should be deducted not less than 50 times, self absorption background deduction method

Power Source220V±22V AC
Shipping Size(W×D×H)(mm)860×705×755(Main instrument)
1170×645×900(Accessories)
G.W. (kg)105 (Main instrument); 100 (Accessories)
Flame System
Acetylene Air Burner100mm
Lgnition Dynamic Baseline Drift≤0.006A/30min
(Cu) Characteristic Viscosity≤0.025μg/ml/1%
Related Standard Deviation of the Accuracy≤0.5% (Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Safety System

Can automatically cut off the gas when the pressure is not enough the power is off flame out and unconformity of the burner

Graphite Furnace
The Highest Temperature3000℃
The Largest Temperature Rising Speed≥2000℃/s
Characteristic QuantityCd≤0.5×10-12g Cu≤0.5×10-11g
AccuracyCu≤3% Cd≤3%
Size (mm) and Weight730×625×700; 79.3kg
Safety SystemOver current protection
Low air pressure alarm/protection
Low cooling water flow alarm/protection
Power Source and Power220V±22V AC 7000W

Atomic Absorption Spectrophotometer Features:

The atomic absorption spectrophotometer is PC-controlled and uses advanced graphite furnace temperature control technology. Its unique optical and mechanical design and various convenient features make it ideal for various industries. Here are some of its features:


1. Complete automatic control system, fully PC controlled. You can quickly realize:

  • Automatic ignition and extinguishing

  • Graphite furnace test method setting wavelength scanning and peak seeking determination

  • Selection of atomizer

  • Gas flow control

  • Advanced graphite furnace temperature control technology

  • The setting of the background deduction method

  • Elevator up and down front and back adjustment

  • Adjustment of light energy

2. Integrated floated optical platform design can improve the visual system shock resistance and keep it stable though using the optical signal for a long time.

3. The flame burner can automatically adjust the optimum height

4. Simultaneous preheating of eight lamps with automatic change of selection

5. Fully automatic peak search and wavelength scanning

6. Full range of safety features, including flame anomalies, gas leaks, under-pressure alarms and automatic safety protection.

7. Self-absorbing background and deuterium lamp adjustment

8. Superior data processing capability


Advanced Graphite Furnace Temperature Controlling Technology

1. PID technology ensures more accurate temperature control even with voltage fluctuations and resistance changes.

2. Fast sampling techniques are used to obtain reliable test data

3. The furnace has a fast heat-up capability for increased component flexibility

4. It can be powered by a 220V power supply with a maximum heating capacity set to 20 levels for testing different samples

5. Can adjust the gas flow  to three different levels to suit a variety of applications

6. The Atomic absorption spectrophotometer has an alarm system that alerts the user during a low gas or water supply.


Safe and reliable flame system

1. EPC for more precise control of acetylene (C2H2) flow and easier handling

2. Highly efficient atomization system for higher sensitivity

3. High safety with automatic alarms for flame anomalies, power failures, insufficient pressure, etc.

4. Automatic gas shut-off in case of abnormality


Multifunctional Software Workstation

Supports WINDOWS7

1. Rich menus make operation more convenient

2. Convenient conversion between different menus makes the process easier.

3. Multiple analysis and correction methods provide users with more choices.

4. Supports flexible storage and editing