Range : 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Accuracy : ±1% F.S.
Calibration Points : 1 to 3 points (84µS/cm, 1413uS/cm, 12.88mS/cm, 111.8mS/cm)
Sizes(W×D×H)(mm) : 96x96x75
Online Conductivity Meter Specifications:
| Model | CON-O650 | |
|---|---|---|
| Conductivity | Range | 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
| Resolution | 0.001, 0.01, 0.1, 1 | |
| Accuracy | ±1% F.S. | |
| Calibration Points | 1 to 3 points (84µS/cm, 1413uS/cm, 12.88mS/cm, 111.8mS/cm) | |
| TDS | Range | 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
| Resolution | 0.01,0.1,1 | |
| Accuracy | ±1% F.S. | |
| TDS Factor | 0.1~1.0 (default 0.5) | |
| Temperature | Range | 0~100°C/32~212°F |
| Resolution | 0.1°C/0.1°F | |
| Accuracy | ±1°C/±1.8°F | |
| Offset Calibration | 1 point, reading ±10°C | |
| Communication | Signal Output | 4~20mA |
| Load | Max. 500Ω | |
| Low or High Alarm | 0.02µS/cm~20.0mS/cm, selectable | |
| Communication Interface | RS485 | |
| Connection Terminals | Detachable screw terminals | |
| Other Specifications | Temperature Compensation | 0~100°C, automatic |
| Environmental Conditions | Ambient temperature <60°C, relative humidity< 80% | |
| Power Requirements | DC24V | |
| Sizes(W×D×H) | 96x96x75 | |
| Shipping Size (W×D×H)(mm) | 280x220x150 | |
| N.W./G.W. (kg) | 0.35/1.5 | |
Online Conductivity Meter Features:
This is suitable for industrial use online conductivity meter 4 to 20mA signal output. The meter is suitable for metallurgy, chemical, pharmaceutical, food, and environmental protection industries to monitor the conductivity of water and total dissolved solids value.
Economical industrial online conductivity meter with platinum conductivity electrode.
1 to 3 point calibration, automatic recognition of conductivity standards.
Selectable electrode constants (K=0.1/1/10), temperature compensation factor and TDS conversion factor.
Automatic temperature compensation, corrects conductivity measurements and converts readings to reference temperature.
High or low alarm limits, customizable hysteresis.
RS485 communication with 4 to 20mA signal output.
Setup menu with a customizable number of calibration points, temperature units, etc.
Reset function automatically restores meter to factory default settings.