Hand Held Refractometer (tlead-0642) Products
Name Hand Held Refractometer
Code tlead-0642
Type Standard
Brand Amtast
Category Test Instruments
subcategory Refractometer -Hand Held
Unit pcs (pcs)
In Stock Yes
Berminat hub kami: wa chat
Product details for Invoice
Hand Held, Refractometers, Brix, Honey, Salinity
Product Details
Hand Held Refractometers
 
The Hand Held Refractometers are specially designed for measuring the concentration of many kinds of solution listed as following: Juices, Beverages, Honey, Salt water, Brine, Cleaning fluid, battery fluid, Antifreeze and Industrial fluids etc. And they can also test for the proportion of the water-soluble solution. They can be easily used and they are competitive in price. You only need to drop some liquid on the prism and then make it towards to the sunlight. Then the reading of the concentration will appear. ATC means Automatic Temperature Compensation.
 
1. For Brix
ModelRangeResolutionAccuracy
RHB-80ATCBrix 0~80%0.5%±0.5%
RHB-90ATCBrix 0~90%0.5%±0.5%
RHB-90SBrix 0~42; 42~71; 71~90%0.2%±0.2%
RHB-80SBrix 0~50; 50~80%0.2%±0.2%
RHB-10ATCBrix 0~10%0.10%±0.10%
RHB-18ATCBrix 0~18%0.10%±0.10%
RHB-20ATCBrix 0~20%0.10%±0.10%
RB-32ATCBrix 0~32%0.20%±0.20%
RHB-50ATCBrix 0~50%0.5%±0.5%
RHB-62ATCBrix 28~62%0.2%±0.2%
RHB-82ATCBrix 45~82%0.5%±0.5%


2. Beer Refractometer 
ModelRang Min.Div.Accuracy
AMR008Brix: 0~32%0.2%±0.2%
SG: 1.000~1.1200.001±0.001

3. Salinity Refractometer
ModelRangeResolutionAccuracy
RHSA-4ATCSalinity 0~40‰1‰±1‰
Gravity 1.000~1.0300.001±0.001
RHS-10ATCSalinity 0~100‰1‰±1‰
Gravity 1.000~1.0701‰±1‰
RHS-10BATCBrix 0~10%0.2%±0.2%
Salinity 0~100‰1‰±1‰
Gravity 1.000-1.0700.001±0.001
RHS-28ATCSalinity 0~28%0.2%±0.2%
RHS-28BATCSalinity 0~28%0.2%±0.2%
Brix: 0~32%0.2%±0.2%
RHS-35ATCSalinity 0~35%0.5%±0.5%
Note: RHSA-4ATC popular for aquarium; RHS-35ATC popular for food indstry.


4. Clinical Protein Refractometer

ModelRangeResolutionAccuracy
VUR1TSerum Protein 0~12g/dl0.2±0.2
Urine Gravity 1.000~1.040sg0.002±0.002
VUR2TSerum Protein 0~12g/dl0.2±0.2
Urine Gravity 1.000~1.050sg0.002±0.002
Refractive Index1.3330~1.3600RI0.0005±0.0005
VUR3TSerum Protein 0~12g/ml0.2±0.2
Urine Gravity 1.000~1.050UG0.002±0.002
Refractive Index: 1.3330~1.3600nD0.0005±0.0005
VUR4TSerum Protein: 0~12g/dl0.2±0.2
Urine Gravity 1.000~1.040UG0.002±0.002
Refractive Index 1.3330~1.3600nD0.0005±0.0005


5. PET (CAT, DOG) Clinical Protein Refractometer
ModelRang Min.Div.Accuracy
AMR016Serum Protein/Plasma: 2~14gms/100ml0.1±0.1g/dl
Cat Urine Gravity: 1.000~1.0600.001±0.001sg
Dog Urine Gravity: 1.000~1.060

 

6. Automotive AdBlue / DEF Urea Concentration Test Meter 
Model  Range    Min Div.   Remark 
   AMR001      Urea: 0~40%   0.2%   ATC, Urea 32.5%   
AMR002Urea: 0~40%0.2%ATC, Urea 32.5%
   EG: -60°F ~ 32°F   10°FATC
PG: -50°F ~ 0°F10°F
AMR003Urea: 0~40%0.2%
EG: -50°C ~ 0°C5°C
PG: -50°C ~ 0°C5°C
CW: -40°C ~ 0°C10°C
AMR004Urea: 30-35%0.2%
EG: -50°C ~ 0°C5°C
PG: -50°C ~ 0°C5°C
CW: -40°C ~ 0°C10°C
   BF: 1.10 ~ 1.40Kg/L      0.01Kg/L   


7. Milk Refractometer

ModelRangeMin. Div.Remark
AMR005Soy Milk: 0~25%0.5%ATC
Brix: 0~32%0.2%
AMR006Water in Milk: 0~20%0.2%ATC


8. Battery/Antifreeze/Cleaning Fluid Refractometer

RHA-100ATC
Ethylene Glycol: -84°F~32°F
Propylene Glycol: -60°F~32°F
Battery: 1.100~1.400sg
Ethylene Glycol: 5°F
Propylene Glycol: 5°F
Battery: 0.01sg
Ethylene Glycol: ±5°F
Propylene Glycol: ±5°F
Battery: ±0.01sg
ATC
RHA-200ATC
Ethylene Glycol: -60°C~0°C
Propylene Glycol: -50°C~0°C
Battery: 1.100~1.400sg
Ethylene Glycol: 5°C
Propylene Glycol: 5°C
Battery: 0.01sg
Ethylene Glycol: ±5°C
Propylene Glycol: ±5°C
Battery: ±0.01sg
ATC
RHA-503C
Battery: 1.100~1.400sg
Ethylene Glycol: -50°C~0°C
Propylene Glycol: -50°C~0°C
Cleaner: -40°C~0°C
Battery: 0.01sg
Ethylene Glycol: 5°C
Propylene Glycol: 5°C
Cleaner: 5°C
Battery: ±0.01sg
Ethylene Glycol: ±5°C
Propylene Glycol: ±5°C
Cleaner: ±5°C
ATC
VBC8
B: 1.000~1.400sg
A: 0%~100%
F: -60°C~0°C
0.01sg
5%
5°C
±0.01sg
±5%
±5°C
ATC


9.  Brake Fluid Checker

ModelRangeMin.Div.Remark
VBK1
DOT3: 1~6% Moisture
          Boiling Point: 250~500°F 
Super DOT3: 1-6% Moisture
          Boiling Point: 250-570°F
1%ATC
VBK2
DOT3: 1-6% Moisture
          Boiling Point: 125-275°C 
Super DOT3: 1-6% Moisture
          Boiling Point: 150-275°C
1%ATC


10. Alcohol Refractometer 

ModelRangeMin.Div.Accuracy
RHW-80w/w: 0-50%, 50-80%0-50%: 1%; 50-80%: 2.5%±1%
    


11. Refractive Index

ModelRangeMin.Div.Accuracy
VND1nD.1.333-1.5200.001±0.002 ATC
VND2nD.1.333-1.3800.001±0.002 ATC
VND4nD.1.435-1.5200.001±0.002 ATC


12. Bee Honey Refractometer

ModelRangeMin.Div.Accuracy
RHH13-25water: 13~25%water: 0.1%water: ±0.1%
RHH12-30water: 12~30%water: 0.1%water: ±0.1%
RHH-92ATC
Brix: 58~92%
Baume: 38~43Be'
water: 12~27%
Brix: 0.5%
Baume: 0.5Be'
Water: 1%
Brix:: ±0.5%
Baume: ±0.5Be'
Water: ±1%
RHH-90ATC
Brix: 58~90%
Baume: 38~43Be'
water: 12~27%
Brix: 0.5%
Baume: 0.5Be'
Water: 1%
Brix: ±0.5%
Baume: ±0.5Be'
Water: ±1%


13. Wine Refactometer

ModelRangeMin.Div.AccuracyRemark
RHW-25aATC
Alcohol 0~25%VOL
Alcohol 0.2% 
Alcohol ±0.2% 
ATC
Baume 0~20Baume 

Sharing is caring, show love and share the product with your friends.

-->