Bante900P Portable Multiparameter Water Quality Meter (bante-0110) Products
Name Bante900P Portable Multiparameter Water Quality Meter
Code bante-0110
Type Standard
Brand Bante
Category Multiparameter Meters
subcategory Portable Meters
Unit pcs (pcs)
In Stock Yes
Berminat hub kami: wa chat
Product details for Invoice
High-performance multiparameter water quality meter contains 8 measurement modes, suitable for measuring pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and dissolved oxygen.
Product Details

Bante900P Portable Multiparameter Water Quality Meter

High-performance multiparameter water quality meter contains 8 measurement modes, suitable for measuring pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and dissolved oxygen.

pH Mode:
• Portable multiparameter water quality meter is equipped with a backlit LCD display.
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
• Automatic electrode diagnosis shows the pH slope and zero offset.

ORP Mode:
• 1 point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt modes ensure the reliable ORP measurements.

Portable Multiparameter Water Quality Meter

Ion Concentration Mode:
• 2 to 5 points calibration, including the selection of 8 concentration points.
• Automatic electrode diagnosis shows the calibration points and slopes.
• Direct ion concentration readout simplifies the measurement process.
• Selectable concentration units (ppm, mg/L, mol/L) and ionic valency.

Conductivity/TDS/Salinity/Resistivity Modes:
• 1 to 5 points calibration with automatic recognition for conductivity standards.
• Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear and
  pure water compensations, seawater and practical salinity measurement modes.

Dissolved Oxygen Mode:
• 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
• Salinity and barometric pressure compensations eliminate the measurement errors.

Portable Multiparameter Water Quality Meter

Other Features:
• Automatic temperature compensation ensures accurate readings over the entire range.
• Auto-read function senses and locks the measurement endpoint.
• Calibration due alarm reminds the user to calibrate the meter regularly.
• Auto-power off effectively conserves battery life.
• Setup menu allows setting the number of calibration points, stability criteria, temperature unit,
  date and time, etc.
• Reset function automatically resumes all settings back to the factory defaults.
• Expanded memory stores or recalls up to 500 data sets.
• USB communication interface is easy to transfer data to a PC.
• Multi-mode power scheme (batteries, power adapter, USB port) ensures the smooth operation
  of the meter.

Specification

   Model


Bante900P

   pH



   Range


-2.000 to 20.000 pH

   Resolution


0.001 / 0.01 / 0.1 pH, selectable

   Accuracy


±0.002 pH

   Calibration


1 to 5 points

   pH Buffer Options


USA / NIST / DIN / 2 custom buffers

   ORP



   Range


-1999.9 to 1999.9 mV

   Resolution


0.1 / 1 mV, selectable

   Accuracy


±0.2 mV

   Calibration


1 point

   Measurement Modes


Relative / Absolute mV

   Ion Concentration



   Range


0.00 to 19999 (depending on the range of ISE)

   Resolution


0.001, 0.01, 0.1, 1, automatic

   Accuracy


±0.5% F.S. (monovalent), ±1% F.S. (divalent)

   Calibration


2 to 5 points

   Calibration Solutions


0.001 / 0.01 / 0.1 / 1 / 10 / 100 / 1000 / 10000

   Measurement Units


ppm, mg/L, mol/L, mmol/L

   Conductivity



   Range


0 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm

   Resolution


0.001, 0.01, 0.1, 1, automatic

   Accuracy


±0.5% F.S.

   Calibration


1 to 5 points

   Calibration Solutions


10 µS / 84 µS / 1413 µS / 12.88 mS / 111.8 mS

   Temperature Coefficient


0.0 to 10.0%/°C

   Pure Water Compensation

Yes

   Reference Temperature

20 / 25°C

   Cell Constant  

K=0.1 / 1 / 10 / Custom

   TDS



   Range


0 to 10.00, 100.0, 1000 ppm, 10.00, 200.0 ppt

   Resolution


0.01, 0.1, 1, automatic

   Accuracy


±1% F.S.

   TDS Conversion Factor


0.1 to 1.0 (default 0.5)

   Salinity



   Range


0.00 to 80.00 ppt / 0.00 to 42.00 psu

   Resolution


0.01

   Accuracy


±1% F.S.

   Resistivity



   Range


0.00 to 20.00 MΩ

   Resolution


0.01

   Accuracy


±1% F.S.

   Dissolved Oxygen



   Range


0.00 to 20.00 mg/L / 0.0 to 200.0 % saturation

   Resolution


0.01 / 0.1, selectable

   Accuracy


±0.2 mg/L / ±2.0 %

   Calibration


1 or 2 points

   Pressure Correction


60.0 to 112.5 kPa / 450 to 850 mmHg, manual

   Salinity Correction


0.0 to 50.0 g/L, manual

   Temperature



   Range


0 to 105°C / 32 to 221°F

   Resolution


0.1°C/°F

   Accuracy


±0.5°C / ±0.9°F

   Calibration


1 point

   Calibration Range


Reading ±10°C/°F

   Other Specifications



   Temperature Compensation


0 to 100°C / 32 to 212°F, manual or automatic

   Hold Function


Manual / Auto-read measurement endpoint

   Stability Criteria


Low / High

   Calibration Due Alarm


1 to 31 days or off

   Auto-Power Off


10 / 20 / 30 minutes after last key pressed

   Memory


Stores up to 500 data sets

   Output


USB communication interface

   Connector


BNC, 6-pin mini-DIN, 3.5 mm jack socket

   Display


Custom LCD (80 × 60 mm)

   Power Supply


3 × 1.5V AA batteries or 5V DC power adapter

   Battery Life


Approximately 150 hours without backlight

   Environmental Conditions


0 to 50°C / 32 to 122°F, relative humidity < 80%

   Dimensions


170 × 85 × 30 mm

   Weight


300 g

Ordering Info

   Ordering Code

Meter Includes

   Bante900P-CN

E201-BNC pH electrode

CON-1 conductivity electrode

DO100 dissolved oxygen electrode

TP-10K temperature probe

pH 4.01, 7.00, 10.01 buffer reagents

Conductivity standard solutions 84 µS/cm, 1413 µS/cm, 12.88 mS/cm

DO electrolyte solution

DO membrane cap

Electrode clip

Carrying case

   Bante900P-UK

   

P11 glass pH electrode

K10 conductivity electrode

DO100 dissolved oxygen electrode

TP-10K temperature probe

pH 4.01, 7.00, 10.01 buffer reagents

Conductivity standard solutions 84 µS/cm, 1413 µS/cm, 12.88 mS/cm

DO electrolyte solution

DO membrane cap

Electrode clip

Carrying case

Optional Accessories

ItemsDescription
E201-BNC pH ElectrodeFor measuring the liquids
E202-BNC pH ElectrodeFor measuring the semisolid and gel samples
P11 pH ElectrodeFor measuring the weak corrosive samples
P11-LiCl pH ElectrodeFor measuring the non-aqueous samples
P11-HA pH ElectrodeFor measuring the high alkalinity samples
P11-NA pH ElectrodeFor measuring the biofuels
P13 pH ElectrodeFor measuring the micro-volume samples
P15 pH ElectrodeFor measuring the low conductivity samples
P16 pH ElectrodeFor measuring the Tris buffers
P19 pH ElectrodeFor measuring the semisolid samples
P22 pH ElectrodeFor measuring the high temperature samples
501 ORP ElectrodeFor measuring samples with weak redox potential
502 ORP ElectrodeFor measuring samples with strong redox potential
ISE-NH3 Ammonia ElectrodeRange: 0.01 to 17000 ppm
ISE-NH4 Ammonium ElectrodeRange: 0.1​ to 18000 ppm
ISE-Br Bromide ElectrodeRange: 0.4 to 81000 ppm
ISE-Cd Cadmium ElectrodeRange: 0.1 to 11200 ppm
ISE-Ca Calcium ElectrodeRange: 0.02 to 40100 ppm
ISE-Cl Chloride ElectrodeRange: 1 to 35000 ppm
ISE-Cu Copper ElectrodeRange: 0.06 to 6400 ppm
ISE-CN Cyanide ElectrodeRange: 0.03 to 260 ppm
ISE-F Fluoride ElectrodeRange: 0.02 to 1900 ppm
ISE-I Iodide ElectrodeRange: 0.06 to 127000 ppm
ISE-Pb Lead ElectrodeRange: 0.2 to 20800 ppm
ISE-NO3 Nitrate ElectrodeRange: 0.4 to 62000 ppm
ISE-K Potassium ElectrodeRange: 0.04 to 39000 ppm
ISE-Ag Silver ElectrodeRange: 0.01 to 107900 ppm
ISE-Na Sodium ElectrodeRange: 0.002 to 69000 ppm
ISE-S Sulfide ElectrodeRange: 0.003 to 32000 ppm
CON-0.1 Conductivity ElectrodeFor measuring the pure water
CON-1 Conductivity ElectrodeFor measuring the general water samples
CON-10 Conductivity ElectrodeFor measuring the high conductivity samples
DO100 Dissolved Oxygen ElectrodeFor measuring the DO and % saturation of oxygen
TP-10K Temperature ProbeFor temperature compensation and measurement
pH Buffer SolutionsFor pH calibration
pH Electrode Storage SolutionFor electrode maintenance and storage
pH Electrode Cleaning SolutionFor general cleaning
pH Electrode Cleaning SolutionFor removing the protein contamination
Ion Standard SolutionsFor ion concentration calibration
Ionic Strength AdjustersFor adjusting the pH and background ionic strength
Conductivity Standard SolutionsFor conductivity calibration
DO Electrolyte SolutionFor filling the dissolved oxygen electrode
DO Membrane CapFor polarographic dissolved oxygen electrode
USB CableFor transferring data or connecting power adapter
5V DC Power AdapterFor connecting external power source

Packaging

   Ordering Code

Dimensions and Weights

   Bante900P-CN

45 × 32 × 10 cm, 2 kg

   Bante900P-UK

45 × 32 × 10 cm, 2 kg