| Name | Automatic Anaerobic Chamber |
| Code | scitek-0001 |
| Type | Standard |
| Brand | Scitek |
| Category | Incubators |
| subcategory | Anaerobic Incubator |
| Unit | pcs (pcs) |
| In Stock | Yes |
| Berminat hub kami: | |
Operation Chamber Size(W×D×H) : 950x680x750mm
Power Rating : 800W
Time for Creating Anaerobic State in Sample Chamber : <10 minutes
Temperature Range : RT+3~60℃
The anaerobic chamber provides a leak-proof physical barrier that protects the operator from harmful airborne particles and powders.
Anaerobic Chamber Specifications:
| Model | ICB-3AN |
|---|---|
| Anaerobic State Creating | Automatic |
| Time for Creating Anaerobic State in Sample Chamber | <10 minutes |
| Time for Creating Anaerobic State in Operation Chamber | <1.5 hrs |
| Anaerobic Environment Maintenance Time | >12 hrs.(when no supply of mixed gas) |
| Temperature Range | RT+3~60℃ |
| Temperature Stability | <±0.3℃ |
| Temperature Uniformity | <±1 ℃ |
| O2 Control Range | <1% |
| Timing Range | 1~9999min |
| Power Rating | 800W |
| Power Supply | AC 220V, 50Hz |
| Internal Chamber Size (W×D×H)(mm) | 420x300x500 |
| Operation Chamber Size (W×D×H)(mm) | 950x680x750 |
| External Size (W×D×H)(mm) | 1400x730x1380 |
| Shipping Size (W×D×H)(mm) | 1510x910x1610 |
| N.W./G.W. (kg) | 255/315 |
Anaerobic Chamber Features:
Microprocessor controller for accurate temperature and gas control in the incubator.
Anaerobic Chamber is equipped with a large color touch screen for easy operation.
Imported oxygen sensor and high precision temperature sensor for accuracy, stability, and security.
Automatic gas replacement control.
Unique oil bottle type pressure relief design for internal pressure protection and air leakage prevention.
UV sterilizer for effective bacterial contamination prevention.
Stainless steel cultivation and operation room with transparent impact-resistant glass front window for easy observation. Latex gloves for comfortable and reliable use.
Deoxidization catalyst in the operation room.
Unique track design for easy sample transfer.
Sample transfer capability: 40 pcs of 90mm plates at a time.
The ICB-3AN anaerobic chamber is equipped with leakage protection function and USB interface for data storage up to 6 months.
Special inoculating rod sterilizer and wax melting disinfection device in the operating room.
Arabic
French
German
Indonesian
Italian
Portuguese-brazilian
Simplified-chinese
Spanish
Thai
Traditional-chinese
Turkish
Vietnamese